Tritec’s fully trained thermographic survey staff provides worldwide inspection and analysis of machinery and plant, marine and shore based for detection of ‘hot spots’. Typical items surveyed:
- High temperature surface insulation for detection of temperatures above 220 degrees C (SOLAS, Regulation 4, section 2.2.6).
- Electrical switch boards, distribution boards etc for detection of loose electrical connections, short circuits and 3 phase power imbalance
- Pre-drydock survey of electrical installations
- Periodic thermographic surveys as part of a condition based monitoring or planned maintenance programme.
- Detection of steam heating system blockages at steam traps.
- Detection of refrigeration system blockages.
- Misaligned rotating machinery couplings